Transducers
- SENSOTEC - A5/744-1 - Transducers, pressure. 0-200PSI, +/ -15 or 28VDC.Special Price $279.99 Regular Price $355.00Transducers, pressure. 0-200PSI, +/ -15 or 28VDC. Learn More
- SENSOTEC - 811-FMA/1042-17-01 - Strain Gage, 500 KPAA Pressure Transmitter$398.00Transducer. Bonded foil strain gage. Range: 500 KPAA. Output: 4-20mA. Supply: 15-50VDC. Outdoor and hazardous locations, Class I, II and III. Bonded Foil Strain Gage, two wire and ground. Resolution: Infinite. Temperature, Operating: 0� F to 180� F. Temperature, Compensated: 60� F to 160� F. Size: 2.26"D x 5.8"L, 7.7"L with cable strain relief. Weight: 2 lbs before packing. Learn More
- Logan Lundahl Instruments - DCU-A - 6-Wire Ultrasonic TransducersSpecial Price $184.98 Regular Price $248.95
Logan Lundahl Instruments - DCU-A - 6-WIRE ULTRASONIC SENSORs with Adjustable Trip-point and Sensitivity.
The DCU series sensors use ultrasonic technology to provide a non-contact method of determining distance or level measurements.
Dimensions: 2" Square x 3.6" Long.
A Division of EZRA C LUNDHAL, INC
Note: California-based Scientific Technologies Inc aquired Logan Lundahl Instruments.
New Old Stock - Made in USA
Learn More - KEYENCE - AT-210 - Digital Contact Sensor Amplifier Control Module, w/9 foot 4 conductor cable, NewSpecial Price $329.98 Regular Price $450.00
KEYENCE - AT-210 - Digital Contact Sensor Amplifier Control Module.
Status: Discontinued
Output Voltage: -0.5 ~ +0.5 V.
Output Impedance: 300 Ohm.
Supply voltage: DC12-24V, 10% ripple (PP) 10%.
Measurement Range: -5.0 to +5.0 mm-0.197" to 0.197"
Analog Output Voltage
Output Voltage: -0.5 to +0.5 V
Impedance: 300 Ω
Resolution: 10 µm 0.39 Mil
Linearity: 0.8% of F.S.
Response: DC to 800 Hz (-3 dB)
Measurement Force: 0.28N*1
Temperature Characteristics: 0.03% of F.S./°C*2
Connection Cord Length: 3 m
Power Voltage: 12 to 24 VDC ±10 %, Ripple (P-P) 10 %
Current Consumption: 50 mA or less
Ambient Temperature: 0 to +50 °C 32 to 122 °F
Relative Humidity: 35 to 85 % RH (No condensation)
Din Rail Mount
Dimensions: Width:7.00 (in)Height:6.00 (in)Depth:7.00 (in)
Weight: Approx. 100 g
Complete with a 4 conductor cable 9 foot, and attached 4 pin male micro connector.
Made in Japan
UPC 646412786394New
Learn More - VALIDYNE - DP45-16-2114 - Gould 369500-57035- Transducer, Low Differential Pressure. 3.5CM. NewSpecial Price $289.98 Regular Price $350.00
VALIDYNE - DP45-16-2114 - Gould 369500-57035 - Transducer, Low Differential Pressure.
The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of ±1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.
All surfaces exposed to the media are corrosion resistant steel. The design and construction of the DP45 permits the user to disassemble the instrument for cleaning, diaphragm replacement, or changing the transducer range. The transducer range is changed by substituting a different sensing diaphragm chosen from the Diaphragm Selection Chart on the reverse side of this sheet.
Used with a typical Validyne carrier demodulator, pressure inputs as low as 0.6 in. H2O will produce up to a ±10V output. The exceptionally low acceleration sensitivity of the DP45 ensure accuracy under all types of mounting conditions.
- Low range: ±0.6 to 90 in.H2O FS
- Low internal volume
- Symmetrical construction
- Small volumetric displacement
- High natural frequency
3.5CM.
Electrical Connector PT06A-10-6S
Mounting: Three Holes 6-32unc-28X.20 Deep ON 1.75- Diameter.
Dimensions: 57mm Diameter (2.24")
Additional Information https://www.validyne.com/product/dp45_low_pressure_variable_reluctance_sensor/
Alternate P/N: Gould 369500-57035.
Made in USA - Factory New With Specifications & Installation Drawing
Learn More - LEM - LF1005-S/SP21 - Transducer, current. Up to 1000Amp.$200.00Out of stockTransducer, current. Up to 1000Amp. Hall effect. Closed loop. For the electronic measurement of currents: DC, AC, pulsed, with galvanic isolation between the primary circuit (high power) and the sedondary circuit (electronic circuit). Application: AC variable speed drives and servo motor drives. Static converters for DC motor drives. Battery supplied applications. Uninterruptible power supplies (UPS). Switched mode power supllies (SMPS). Power supplies for welding applications. New. Learn More
- Lem Sa - CV3-500 - Transducer, voltage.$400.00Out of stockTransducer, voltage. Primary: 350Vrms. Ratio: 10V/500V. Insulation: 6 kV rms 60s. For the electronic measurement of voltages : DC, AC, pulsed, with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Learn More
- Lem Sa - CV3-200 - Transducer, voltage.$400.00Out of stockTransducer, voltage. Primary: 140Vrms. Ratio: 10V/200V. Insulation: 6 kV rms 60s. For the electronic measurement of voltages : DC, AC, pulsed, with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Learn More
- American Aerospace Controls Inc - 415A-10-230 - Watt Transducer$300.00Watt Transducer. Frequency 60Hz, Rated 2KW 230VAC 10Amp. Voltage limits: 160-300VAC. Power Factor range: 1-0. Scale Factor: 2500mV/KW. Note: Manuf: ACC. Learn More
- American Aerospace Controls Inc - 415A-10-115 - Watt Transducer.$300.00Watt Transducer. Frequency 60Hz, Rated 1KW 115VAC 10Amp. Voltage limits: 80-150VAC. Power Factor range: 1-0. Scale Factor: 5000-1mV/KW. Note: Manuf: ACC. Learn More