Transducers

Filter  
  1. Price $200.00 - $0.00 Remove This Item
Clear All
VAC  
DC Voltage  
Hz  
PSI  
Manufacturer  
Amperage  
Unit of Measure  
Price  
View as List Grid

9 Items

per page
Set Descending Direction
  1. SENSOTEC - A5/744-1 - Transducers, pressure. 0-200PSI, +/ -15 or 28VDC.
    SENSOTEC - A5/744-1 - Transducers, pressure. 0-200PSI, +/ -15 or 28VDC.
    Special Price $279.99 Regular Price $355.00
    Transducers, pressure. 0-200PSI, +/ -15 or 28VDC. Learn More
  2. SENSOTEC - 811-FMA/1042-17-01 - Strain Gage, 500 KPAA Pressure Transmitter
    SENSOTEC - 811-FMA/1042-17-01 - Strain Gage, 500 KPAA Pressure Transmitter
    $398.00
    Transducer. Bonded foil strain gage. Range: 500 KPAA. Output: 4-20mA. Supply: 15-50VDC. Outdoor and hazardous locations, Class I, II and III. Bonded Foil Strain Gage, two wire and ground. Resolution: Infinite. Temperature, Operating: 0� F to 180� F. Temperature, Compensated: 60� F to 160� F. Size: 2.26"D x 5.8"L, 7.7"L with cable strain relief. Weight: 2 lbs before packing. Learn More
  3. KEYENCE - AT-210 - Digital Contact Sensor Amplifier Control Module, w/9 foot 4 conductor cable, New
    KEYENCE - AT-210 - Digital Contact Sensor Amplifier Control Module, w/9 foot 4 conductor cable, New
    Special Price $329.98 Regular Price $450.00

    KEYENCE - AT-210 - Digital Contact Sensor Amplifier Control Module.

    Status: Discontinued

    Output Voltage: -0.5 ~ +0.5 V.

    Output Impedance: 300 Ohm.

    Supply voltage: DC12-24V, 10% ripple (PP) 10%.

    Measurement Range: -5.0 to +5.0 mm-0.197" to 0.197"

    Analog Output Voltage

    Output Voltage:  -0.5 to +0.5 V

    Impedance: 300 Ω

    Resolution: 10 µm 0.39 Mil

    Linearity: 0.8% of F.S.

    Response: DC to 800 Hz (-3 dB)

    Measurement Force: 0.28N*1

    Temperature Characteristics: 0.03% of F.S./°C*2

    Connection Cord Length: 3 m

    Power Voltage: 12 to 24 VDC ±10 %, Ripple (P-P) 10 %

    Current Consumption: 50 mA or less

    Ambient Temperature: 0 to +50 °C 32 to 122 °F

    Relative Humidity: 35 to 85 % RH (No condensation)

    Din Rail Mount

    Dimensions: Width:7.00 (in)Height:6.00 (in)Depth:7.00 (in)

    Weight: Approx. 100 g

    Complete with a 4 conductor cable 9 foot, and attached 4 pin male micro connector.

    Made in Japan

    UPC 646412786394

    New

    Learn More
  4. VALIDYNE - DP45-16-2114 - Gould 369500-57035- Transducer, Low Differential Pressure. 3.5CM. New
    VALIDYNE - DP45-16-2114 - Gould 369500-57035- Transducer, Low Differential Pressure. 3.5CM. New
    Special Price $289.98 Regular Price $350.00

    VALIDYNE - DP45-16-2114 - Gould 369500-57035 - Transducer, Low Differential Pressure.

    The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of ±1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.

    All surfaces exposed to the media are corrosion resistant steel. The design and construction of the DP45 permits the user to disassemble the instrument for cleaning, diaphragm replacement, or changing the transducer range. The transducer range is changed by substituting a different sensing diaphragm chosen from the Diaphragm Selection Chart on the reverse side of this sheet.

    Used with a typical Validyne carrier demodulator, pressure inputs as low as 0.6 in. H2O will produce up to a ±10V output. The exceptionally low acceleration sensitivity of the DP45 ensure accuracy under all types of mounting conditions.

    • Low range: ±0.6 to 90 in.H2O FS
    • Low internal volume
    • Symmetrical construction
    • Small volumetric displacement
    • High natural frequency

    3.5CM.

    Electrical Connector PT06A-10-6S

    Mounting: Three Holes 6-32unc-28X.20 Deep ON 1.75- Diameter.

    Dimensions: 57mm Diameter (2.24")

    Additional Information https://www.validyne.com/product/dp45_low_pressure_variable_reluctance_sensor/

    Alternate P/N: Gould 369500-57035.

    Made in USA - Factory New With Specifications & Installation Drawing

    Learn More
  5. LEM - LF1005-S/SP21 - Transducer, current. Up to 1000Amp.
    LEM - LF1005-S/SP21 - Transducer, current. Up to 1000Amp.
    $200.00
    Transducer, current. Up to 1000Amp. Hall effect. Closed loop. For the electronic measurement of currents: DC, AC, pulsed, with galvanic isolation between the primary circuit (high power) and the sedondary circuit (electronic circuit). Application: AC variable speed drives and servo motor drives. Static converters for DC motor drives. Battery supplied applications. Uninterruptible power supplies (UPS). Switched mode power supllies (SMPS). Power supplies for welding applications. New. Learn More
  6. Lem Sa - CV3-500 - Transducer, voltage.
    Lem Sa - CV3-500 - Transducer, voltage.
    $400.00
    Transducer, voltage. Primary: 350Vrms. Ratio: 10V/500V. Insulation: 6 kV rms 60s. For the electronic measurement of voltages : DC, AC, pulsed, with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Learn More
  7. Lem Sa - CV3-200 - Transducer, voltage.
    Lem Sa - CV3-200 - Transducer, voltage.
    $400.00
    Transducer, voltage. Primary: 140Vrms. Ratio: 10V/200V. Insulation: 6 kV rms 60s. For the electronic measurement of voltages : DC, AC, pulsed, with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Learn More
  8. American Aerospace Controls Inc - 415A-10-230 - Watt Transducer
    American Aerospace Controls Inc - 415A-10-230 - Watt Transducer
    $300.00
    Watt Transducer. Frequency 60Hz, Rated 2KW 230VAC 10Amp. Voltage limits: 160-300VAC. Power Factor range: 1-0. Scale Factor: 2500mV/KW. Note: Manuf: ACC. Learn More
  9. American Aerospace Controls Inc - 415A-10-115 - Watt Transducer.
    American Aerospace Controls Inc - 415A-10-115 - Watt Transducer.
    $300.00
    Watt Transducer. Frequency 60Hz, Rated 1KW 115VAC 10Amp. Voltage limits: 80-150VAC. Power Factor range: 1-0. Scale Factor: 5000-1mV/KW. Note: Manuf: ACC. Learn More