- TDK Lambda - L-12-OV-5 - Overvoltage Protection. 12Amp 5V Hybrid Device.
TDK Lambda - L-12-OV-5 Overvoltage Protection.
12 A 30 Volt 1.0% range: 33.5Volts +/- 1V. A temperature compensating hybrid circuit that resets itself when normal conditions resume.
Temperature Compensated Trip Point
Suitable for any Current Rated Device
No Additional Components Required
Mount: Flange Mount
12Amp 5V Hybrid Device
Trip 6.6V, +/-0.3V.
Case: PCB Mount 1.5" x 0.750" base x 0.676" tall with 1.168" mounting centers.
Genuine TDK Lambda - New Old Stock
Learn More - EATON - CUTLER-HAMMER - HMCP400W5W - Circuit Breaker, Motor Circuit Protector, 3 Pole 400Amp 600VAC/250VDC.Special Price $895.98 Regular Price $1,850.00READY TO SHIP - ONLY 1 LEFT IN STOCK!
CUTLER-HAMMER - HMCP400W5W Circuit Breaker.
3 Pole 400Amp 600VAC/250VDC.
Family: Series C, Nema Type 3, Molded Case.
Phase: 3
Poles: Three - Pole Magnetic Trip
Voltage: 600
Amperage: 400
Connection: Bolt-On
Protection: Magnetic Only
Functions: I - Instantaneous
AIC Rating: 35kA@480V
Frame Size: K Frame
Magnetic Trip Range : 1250-2500 Amp.
Motor Protector. - Approvals: UL, CSA
Dimensions: Height 10.13" X Length 4.1" X Width 5.5"
Weight: 11 Lb 5 Oz
Used / Removed From Equipment
Note: Difficult to find Item
Made in USA
Learn More - TDK Lambda - L-35-0V-5 - Overvoltage Protector Module, IGBTSpecial Price $22.98 Regular Price $28.50
TDK Lambda - L-35-0V-5 - Overvoltage Protector Module, IGBT.
Overvoltage Protection
Range: 6.6V =/-0.2V
Package: Module.
Made in Japan
Typical Applications: Overvoltage Protection used in expensive Voltage Regulated Power Supplies, Standard for 5VDc Power Supplies
NSN 6130-01-115-0946
- POLYPHASER CORP - IS-NEMP-C2 - Nuclear Blast/Lightning Strike Protector 0.2-1GHz
POLYPHASER CORP - IS-NEMP-C2 - High Altitude Nuclear Blast / Lightning Strike Impulse Suppressor.
Coaxial Nuclear EMP Protector. This radio frequency surge protector / lightning surge arrestor helps protect your equipment from electromagnetic pulse (EMP) or power surges that are commonly caused by lightning or other strong electrical changes. Our radio frequency coaxial surge protector product is commonly used for radio and antenna installations where part or all system equipment is outdoors to protect sensitive equipment and is designed to pass 125 MHz to 1 GHz while suppressing DC surge.
Military, government (FEMA and NCA), protection of emergency radio equipment. UL497B listed gas tube, ultra-fast response, and low let through energy. Covers the frequency range of 125 - 1000 MHz.
Surge Protector Type: Gas Discharge Tube
Frequency: 0.2-1GHz
Connector: Equipment Side = Type N Female, Antenna Side = N Female
Impedance: 50 Ohm
125 - 220 MHz @ 200W
220 - 700 MHz @ 100W
700 MHz - 1GMHz @ 50 W
DC-Blocked
Operating Temperature: -50 C to 50 C
Throughput Energy: 250 uJ
This series is capable of 50,000A IEC 1000-4-4 8/20uS waveform surges.
The turn-on voltage is 250V.
Length: 2.72" (69.09mm)
NEW w/Spec.
Approvals: CE Compliant, RoHS Compliant
Applications: HF, UHF, VHF Radios, Ham Radio Protection.
Note: Unit must be properly grounded to low impedance (R&L) ground.
Learn More - ALLEN BRADLEY - AB - 1691-N3 SERIES C - Contact Protector, Snubber, 1 MFD 220-OHMS 150VDC, 120VAC
ALLEN BRADLEY - AB - 1691-N3 Series C Contact Protector / Surge Protector
As a subsidiary of Rockwell International, one of the world's largest technology companies "Allen-Bradley" meets today's challenges of industrial automation with over 85 years of practical plant-floor experience.
Status: Discontinued
Snubber - Time Surge Protector, Two Double (0.110" X 0.032") Tab Terminals
Capacitor 1uF & Resistor 220 OHMS
Maximum Voltage: 120VAC/150VDC
Construction: Sealed Expoxy Enclosure
Mounting: Two Base Holes 0.156" Diameter Spaced 1 9/16" Apart.
Bulletin 1691
Applications: Surge suppressors are used to protect solid state devices against electrical transients which can result whenerver electromechanical devices are operted. Surge Suppressors are for use with relays, timers, AC Contactors,and Starters.
Genuine Allen Bradley - New Old Stock
UL Recognized and CSA Approved
Made in USA
Learn More - Cutler-Hammer / Eaton - 10172H- 10172H 334A - Thermal Overload Switch, 115-230 VAC, 30A, NewSpecial Price $92.98 Regular Price $120.00
Cutler-Hammer / Eaton - 10172H- 10172H 334A - Thermal Overload Switch
Status: Discontinued
Pilot Duty Ratings: 115-230 VAC, 30A
Body Approximate Overall Dimensions: 2.2" x 1.95" X 1.0"
New Old Stock - This Item has no Shelf Life
NSN 5925-00-783-5581
Made in USA
Learn More - POWER-ONE - OVP-12 - OverVoltage Protection for Linear Power Supply, .Special Price $12.98 Regular Price $18.50Out of stock
POWER-ONE - OVP-12 Overvoltage Protection for Linear Power Supply.
Add Over voltage Protection to your power supply.
Status: Discontinued
User Adjustable: 6.4 - 34V
See Attached Datasheet
Applications: Bel Power Solutions Linear Power Supplies and Others
Alternate: 8200003, DigiKey 179-2057-ND, 179-2353
Note: REPLACES 784-OVP-12
New Old Stock - Difficult to Find - Rare
Learn More - Murata Erie - SFE10.7MA21 - Resonator, Ceramic Piezo Filter.
Murata Erie - SFE10.7MA21 - Resonator, Ceramic Piezo Filter.
Status: Discontinued
Wide Bandwidth Series - Through-Hole
Filter Type: Ceramic BPF
Attenuation Frequency (+/- delta f)-Max : 475.0 kHz
Attenuation@Freq-Max: 20.0 dB
Center or Cutoff Frequency (fo/fc): 10.7 MHz
Insertion Loss-Max: 3.0 dB
Genuine Murata Brand
3dB - 400kHz, 20dB - 950kHz.
Learn More - Lambda - L-20-OV-20 - Overvoltage Protector. 20V.READY TO SHIP - ONLY 98 LEFT IN STOCK!
Lambda - L-20-OV-20 - Overvoltage Protector.
The L-20-OV Series of Overvoltage Protectors are hybrid devices designed to prevent damage to a load caused by excessive power supply output voltage. Load protection is accomplished by effectively short circuiting the output terminals of the power supply when the trip point is exceeded. The L-20-OV is reset when s power to the overvoltage protector is interrupted and its case temperature has fallen below 71°C. An external heatsink is required to maintain case temperature below rated limit.
The L-20-OV Series is available for nominal supply voltages from 5 to 30 volts. The trip point voltage is fixed and cannot be adjusted. This two terminal device is available in a hybrid with an isolated flange.
20V, Trip 22.8V +/- 0.7V
On State Current; 20 A
On State Voltage: 1.75V
Non Repetitive Peak Surge Current: 260A
Standby Current: 30 mA
Mount: PCB.
New Old Stock - Difficult to Find.
Learn More - Leader Tech - LT-2791 - EMI Shielding. DX056-13185 Antenna High Power MTU.$0.59 As low as $0.19IN STOCK - MORE THAN 5,000 READY TO SHIP!
Leader Tech - LT-2791 - EMI Shielding EMI Shielding.
Leader Tech (HEICO Company) is a world leading innovator and manufacturer of EMI shielding products for circuit boards, electronic enclosures and interconnect cables.
Antenna High Power MTU Shielding.
Customer P/N DX056-13185. Leader Tech P/N LT-2791
Stainless Steel (Non-Magnetic)
Dimensions: Length 5.212" X Width 0.50" X Depth 0.2875"
New in Manufacturers Factory Packaging.
- SIEMENS - 3NA1002 - Fuse. 500V 40 Amp.$45.00Out of stock
SIEMENS - 3NA1002 Fuse. 500V 40 Amp. Ceramic body, 1-1/6" wide x 1-3/4" deep x 1-13/16" high with additional heavy gauge tabs - overall 3-1/8" high.
Learn More - EATON - CUTLER-HAMMER - Allis Chalmers - H1046 - Heater Coil. Overload Thermal Heating Element.Special Price $89.98 Regular Price $168.50READY TO SHIP - ONLY 16 LEFT IN STOCK!
EATON - CUTLER-HAMMER - Allis Chalmers - H1046 - H1046 - Heater Coil.
H1046, Cutler Hammer, Citation Series, thermal overload heater element, type H, rated for 28.8-36.7 amps, suitable for use with thermal overload relays, magnetic motor starters & motor controls.
Overload Thermal Heating Element for Adjustable Overload Relay.
Enclosure Type: NEMA 00/0/1/1.5/3/4
UPC: 782113212814
Full Load Amps. Minimum: 28.8
Full Load amps. Maximum: 36.7
Brand: Cutler Hammer, Division of Eaton Corp
Item Category: Heater Coil
H x W x D:.8 in x 1.3 in x 2.1 in
Gross Weight:.48 OZ
New Old Stock
Note: Allis Chalmers was the original Manufacturer subsequently acquired by Cuttler Hammer now a Division of Eaton.
Learn More - EATON BUSSMANN - 70P-1 - Telpower Fuse, indicating. 1Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70P-1 - Telpower Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 1Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Pink.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON BUSSMANN - 70M-8 - Telpower Fuse, indicating. 8Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70M-8 - Telpower Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 8Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Brown/White.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON BUSSMANN - 70H-3/4 - Telpower Fuse, Indicating. 3/4Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70H-3/4 - 70F 016 - Telpower® Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 3/4Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Brown.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON BUSSMANN - 70G-1/2 - Telpower Fuse, indicating. 1/2Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70G-1/2 - Telpower Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 1/2Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Red.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON BUSSMANN - 70F-1/4 - 70F 016 - Fuse, indicating. 1/4Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70F-1/4 - 70F 016 - Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 1/4Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Violet.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
Learn More - EATON BUSSMANN - 70D-5 - Telpower Fuse, indicating. 5Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70D-5 - Telpower Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 5Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Grn/Blk.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON BUSSMANN - 70B-2 - Telpower Fuse, indicating. 2Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70B-2 - Telpower Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 2Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: Orange.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- Eaton BUSSMANN - 70A-1-1/3 - Telpower Fuse, indicating. 1-1/3Amp 125VAC 300VDC.
EATON COOPER BUSSMANN - 70A-1-1/3 - Telpower® Fuse, Indicating.
Fast Acting Telecom Telepower Indicating Fuse
Current / Voltage Ratings: 1 1/3 Amp 125VAC 300VDC.
70 Series.
Mounting Type: Holder
Color code: White.
Dimensions: 0.28" (7.1mm) D x 1.86" (47.4mm) long, including pin.
Note: Visual Alarm Indication / Striker Pin.
- EATON- CUTTLER HAMMER - ALLIS-CHALMERS - FH72 - 25-202-555-872 - Heater Coil. Overload Thermal Heating Element.Special Price $16.98 Regular Price $38.50READY TO SHIP - ONLY 5 LEFT IN STOCK!
EATON- CUTTLER HAMMER - ALLIS-CHALMERS - FH72 - 25-202-555-872 - Heater Coil. Overload Thermal Heating Element.
FH72 A200 Series, thermal overload heater element, type FH, rated for 17.5-19.1 amps, suitable for use with thermal overload relays, magnetic motor starters & motor controls.
Technical compatibility with:
A200 series Size 3 overload Relays
A200 series Size 4 oveload Relays
Allis Chalmers was the original manufacturer and acquired by Cuttler Hammer a Division of Eaton.
Proudly Made in USA
Learn More - EATON - CUTTLER HAMMER - ALLIS-CHALMERS - 1236 - H1236 - Heater Coil, Overload Thermal Heating Element.Special Price $16.98 Regular Price $36.50READY TO SHIP - ONLY 1 LEFT IN STOCK!
EATON - CUTTLER HAMMER - ALLIS-CHALMERS - 1236 - H1236 - Heater Coil, Overload Thermal Heating Element.
Status: Discontinued
1236 Heater.
Manual Starter Oberload Relay Heater Coil.
Starter, Citation Series, Heater Coil, 6.12-7.56 Full Load AmpUPC: 78211321954Allis Chalmers was the original Manufacturer acquired by Duttler Hammer a Division of Eaton.
Learn More - SIEMENS ALLIS Industrial Controls - FH34 - 25-107-671-034 - Heater. Overload thermal heating element.Special Price $12.98 Regular Price $18.50READY TO SHIP - ONLY 4 LEFT IN STOCK!
SIEMENS ALLIS Industrial Controls - FH34 - 25-107-671-034 - Heater Coil.
Overload Thermal Heating Element.
The Thermal Overload Relay Heater are for use on Motor Starter (WYLE/SIEMENS)
Learn More - EATON - CUTTLER HAMMER - ALLIS-CHALMERS - FH08 - 25-202-555-8 - Heater Coil. Overload Thermal Heating Element.Special Price $28.98 Regular Price $42.50READY TO SHIP - ONLY 12 LEFT IN STOCK!
EATON - CUTLER-HAMMER - Allis Chalmers - FH08 - 25-202-555-8 - Heater Coil.
Thermal Unit, Full Load Amps 0.46 to 0.50, For Use With Eaton B100 Series Manual Motor Starter (B100M0C, B100M1C, B100S0C, B100S1C, B100W0C, B100W1C, B100U0C, B100U1C, B100J0C, B100J1C, B100M0CA, B100M1CA, B100S0CA, B100S1CA), Sensing Method Bimetallic
UPC #78667862911
Technical compatibility with:
A200 series Size 0 overload Relays
A200 series Size 1 overload Relays
A200 series Size 2 overload Relays
New Old Stock
Note: Allis Chalmers was the original Manufacturer subsequently acquired by Cuttler Hammer a Division of Eaton.
Learn More